<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Jackson Seida, Author at DMC, Inc.</title>
	<atom:link href="https://static.dmcinfo.com/blog/author/jacksons/feed/index.xml" rel="self" type="application/rss+xml" />
	<link></link>
	<description></description>
	<lastBuildDate>Wed, 02 Sep 2026 21:26:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://static.dmcinfo.com/wp-content/uploads/2025/04/site-icon-150x150.png</url>
	<title>Jackson Seida, Author at DMC, Inc.</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How to Commission a WinCC Unified Comfort Panel</title>
		<link>https://static.dmcinfo.com/blog/44303/wincc-unified-comfort-panel-commissioning-settings/</link>
		
		<dc:creator><![CDATA[Jackson Seida]]></dc:creator>
		<pubDate>Wed, 20 May 2026 11:00:00 +0000</pubDate>
				<category><![CDATA[HMI and SCADA]]></category>
		<category><![CDATA[Manufacturing Automation & Intelligence]]></category>
		<category><![CDATA[Siemens PLC]]></category>
		<category><![CDATA[Siemens]]></category>
		<category><![CDATA[Siemens HMI]]></category>
		<category><![CDATA[WinCC Comfort]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/?p=44303</guid>

					<description><![CDATA[<p>Commissioning a WinCC Unified Comfort Panel is one of the last and most critical steps in completing an HMI project. A smooth commissioning process ensures secure communication, reliable runtime behavior, and a system prepared for long-term operation. In this guide, we walk through the essential steps for downloading, configuring, and commissioning a WinCC Unified Comfort [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/44303/wincc-unified-comfort-panel-commissioning-settings/">How to Commission a WinCC Unified Comfort Panel</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Commissioning a WinCC Unified Comfort Panel is one of the last and most critical steps in completing an HMI project. A smooth commissioning process ensures secure communication, reliable runtime behavior, and a system prepared for long-term operation.<a></a></p>



<p class="wp-block-paragraph">In this guide, we walk through the essential steps for downloading, configuring, and commissioning a WinCC Unified Comfort Panel using Siemens TIA Portal. You will learn how to set network parameters, configure users and security, enable encrypted transfers, and successfully load your project to the device. As <a href="https://static.dmcinfo.com/blog/16495/setting-up-basic-user-profiles-and-login-for-wincc-unified-runtime/">Siemens Solutions Partners</a>, we also provide tips for common commissioning tasks to save time and prevent headaches in the field.</p>



<p class="wp-block-paragraph">All example screenshots were captured using TIA Portal V20 and an MTP700 Unified Comfort Panel (6AV2 128-3GB06-0AX1), but the same concepts apply across the WinCC Unified Comfort Panel family.<a id="_msocom_1"></a></p>



<h2 id="h-pre-requisites" class="wp-block-heading">Pre-requisites</h2>



<p class="wp-block-paragraph">Before you begin commissioning, your system must meet certain prerequisites. For instance, your TIA Portal project must be set up with the appropriate hardware, network connections, and screens developed, and your WinCC Unified Comfort Panel must be powered on. Here is how you download your project and commission your WinCC Unified Comfort Panel.</p>



<h2 id="h-change-ip-address" class="wp-block-heading">Change IP Address</h2>



<p class="wp-block-paragraph">On the WinCC Unified Comfort Panel, go to <strong>Network and Internet</strong>, then <strong>Network settings</strong>. Here, select the port you wish to set the IP address for, then select <strong>Specify an IP address</strong>. Enter your desired IP address and subnet mask and click the <strong>Set IP address</strong> button.</p>



<figure class="wp-block-image aligncenter size-full is-resized has-custom-border" style="margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)"><img fetchpriority="high" decoding="async" width="801" height="479" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-1.png" alt="The network settings configuration screen for a Siemens SIMATIC HMI Unified Comfort panel displaying an IP address and Subnet mask." class="has-border-color wp-image-44316" style="border-color:#dfe6ee;border-width:2px;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px;aspect-ratio:1.6179264636263215;object-fit:cover;width:798px" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-1.png 801w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-1-300x179.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-1-768x459.png 768w" sizes="(max-width: 801px) 100vw, 801px" /></figure>



<h2 id="h-configure-users" class="wp-block-heading">Configure Users</h2>



<p class="wp-block-paragraph">To configure users, go to <strong>“Security settings” > “Users and roles”</strong> in the TIA Portal project tree. From there, create an administrator user, set a password, and assign it all roles. Feel free to learn more about Users and roles, by <a href="https://static.dmcinfo.com/blog/16495/setting-up-basic-user-profiles-and-login-for-wincc-unified-runtime/" type="link" id="https://static.dmcinfo.com/blog/16495/setting-up-basic-user-profiles-and-login-for-wincc-unified-runtime/">seeing a previous guide</a> about setting up basic user profiles for WinCC Unified Runtime.</p>



<figure class="wp-block-image aligncenter size-full is-resized" style="margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="1919" height="1038" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-2.png" alt="Siemens TIA Portal V20 user management configuration screen for a Unified Comfort Panel showing create password dialogue box." class="wp-image-44317" style="aspect-ratio:1.8487790131335864;width:1174px;height:auto" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-2.png 1919w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-2-300x162.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-2-1024x554.png 1024w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-2-768x415.png 768w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-2-1536x831.png 1536w" sizes="(max-width: 1919px) 100vw, 1919px" /></figure>



<h2 id="h-configure-encrypted-transfer" class="wp-block-heading">Configure Encrypted Transfer</h2>



<p class="wp-block-paragraph">An encrypted transfer ensures secure download of project files to your WinCC Unified Comfort Panel. On the panel, navigate to <strong>Service and commissioning &gt; Transfer</strong>. Enable the <strong>Enable transfer</strong> checkbox and create a password.</p>



<p class="wp-block-paragraph">In TIA Portal, go to <strong>Runtime settings</strong> under your HMI. In the <strong>General</strong> section, enable the <strong>Activate encrypted transfer</strong> checkbox and enter the same password that you created on your WinCC Unified Comfort Panel.</p>



<figure class="wp-block-image aligncenter size-full is-resized has-custom-border" style="margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="801" height="479" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-3.png" alt="This screen is from the Siemens SIMATIC HMI Unified Comfort panel's Service and Commissioning menu with a red box around 'Enable transfer' and a password field." class="has-border-color wp-image-44318" style="border-color:#dfe6ee;border-width:2px;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px;width:800px" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-3.png 801w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-3-300x179.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-3-768x459.png 768w" sizes="(max-width: 801px) 100vw, 801px" /></figure>



<h2 id="h-download-to-the-unified-comfort-panel" class="wp-block-heading">Download to the Unified Comfort Panel</h2>



<p class="wp-block-paragraph" style="padding-bottom:var(--wp--preset--spacing--40)">Finally, it is time to download your developed screens and configured TIA Portal project to the WinCC Unified Comfort Panel. To do so, click on your HMI in the Project tree, then click the <strong>Download</strong> button in the toolbar. This opens the <strong>Extended download to device</strong> window.</p>



<figure class="wp-block-image aligncenter size-full is-resized" style="margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="1919" height="1040" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-4.png" alt="The General runtime settings for a Siemens SIMATIC HMI Unified Comfort Panel within the TIA Portal engineering software." class="wp-image-44319" style="aspect-ratio:1.8450605075257283;width:1146px;height:auto" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-4.png 1919w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-4-300x163.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-4-1024x555.png 1024w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-4-768x416.png 768w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-4-1536x832.png 1536w" sizes="(max-width: 1919px) 100vw, 1919px" /></figure>



<p class="wp-block-paragraph" style="padding-top:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40)">From here, set the <strong>Type of PG/PC Interface</strong> to PN/IE, and the <strong>PG/PC Interface</strong> to your network adapter, and click <strong>Start search</strong>. If you do not see your device, you can see all compatible devices by selecting the drop-down menu above the table of possible target devices and choosing <strong>Show all compatible devices</strong>. When you see your HMI appear in the table, select it and click <strong>Load</strong>.</p>



<figure class="wp-block-image aligncenter size-full is-resized" style="margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="1919" height="1040" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-5.png" alt="Siemens TIA Portal software interface during an &quot;Extended download to device&quot; operation." class="wp-image-44320" style="width:1164px;height:auto" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-5.png 1919w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-5-300x163.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-5-1024x555.png 1024w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-5-768x416.png 768w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-5-1536x832.png 1536w" sizes="(max-width: 1919px) 100vw, 1919px" /></figure>



<p class="wp-block-paragraph" style="padding-bottom:var(--wp--preset--spacing--40)">In the <strong>Load preview</strong> window, select <strong>Full download</strong> and click <strong>Load</strong>. Check to ensure that the option to download all users and authentication settings is selected. If successful, you should then see your TIA Portal screens loaded onto the WinCC Unified Comfort Panel!</p>



<figure class="wp-block-image aligncenter size-full is-resized" style="margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="790" height="469" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-6.png" alt="Load Preview dialog box in Siemens TIA Portal software, showing the steps required to transfer a project to an HMI device." class="wp-image-44321" style="width:800px" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-6.png 790w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-6-300x178.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-6-768x456.png 768w" sizes="(max-width: 790px) 100vw, 790px" /></figure>



<h2 id="h-trusting-the-plc-communication-certificate" class="wp-block-heading">Trusting the PLC Communication Certificate</h2>



<p class="wp-block-paragraph">By default, the <strong>Only allow secure PG/PC and HMI communication</strong> setting in your TIA Portal project for your PLC is enabled. Enabling this means that during the download of your TIA Portal Project to the PLC and HMI, a PLC communication certificate will be automatically generated and transferred to your WinCC Unified Comfort Panel. But this PLC communication certificate needs to be trusted by completing the following steps.</p>



<p class="wp-block-paragraph" style="padding-bottom:var(--wp--preset--spacing--30)">Go to <strong>Security&gt;Certificates</strong> on the WinCC Unified Comfort Panel. In the <strong>Certificate store</strong> dropdown menu, <strong>select Other Certificates</strong>. Here you should see your certificate, and press <strong>Trust</strong>. Then, restart the HMI runtime software.</p>



<figure class="wp-block-image aligncenter size-full is-resized has-custom-border" style="margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="801" height="479" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-7.png" alt="Security &gt; Certificates section of a Siemens SIMATIC HMI Unified Comfort Panel configuration screen with 'Other Certificates' selected form a Certificates dropdown menu," class="has-border-color wp-image-44322" style="border-color:#dfe6ee;border-width:2px;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px;width:800px" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-7.png 801w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-7-300x179.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-7-768x459.png 768w" sizes="(max-width: 801px) 100vw, 801px" /></figure>



<h2 id="h-additional-settings-to-apply-to-your-hmi-panel" class="wp-block-heading">Additional Settings to Apply to Your HMI Panel</h2>



<p class="wp-block-paragraph">Beyond core commissioning steps, there are a handful of additional settings that can be helpful for further improving system reliability and maintainability. While they aren&#8217;t required for every project, these settings are commonly used to help reduce downtime, manage system access, and recover information and settings in the event of outages or reboots. Consider the settings below as they apply to your unique project requirements. Storage Device Set Up</p>



<h3 id="h-storage-device-set-up" class="wp-block-heading">Storage Device Set Up</h3>



<p class="wp-block-paragraph">When commissioning a WinCC Unified Comfort Panel, it is often recommended to activate the <strong>Automatic Backup</strong> option. This will ensure that the HMI device&#8217;s data is backed up to the storage device. If the WinCC Unified Comfort Panel becomes inoperable, you can simply purchase a replacement and insert it into the new HMI to resume operation.</p>



<p class="wp-block-paragraph">To do this, slot in a SIMATIC HMI Memory (SD) Card into the X50&nbsp;SYSTEM slot of the Unified Comfort Panel. Note, the system memory card of the comfort panel must be a SIMATIC HMI Memory Card.</p>



<p class="wp-block-paragraph">Slotting in the storage device will cause a <strong>System memory card plugged</strong> dialog window to pop up. Click <strong>OK</strong>. This takes you to the settings <strong>Service and Commissioning/ Automatic Backup</strong> screen.</p>



<p class="wp-block-paragraph" style="padding-bottom:var(--wp--preset--spacing--20)">Here, click the <strong>Start</strong> button, and <strong>OK</strong> in the <strong>Start automatic backup</strong> dialog window to activate Automatic Backups. Once preparation is complete, the <strong>Status</strong> box will display automatic backup active.</p>



<figure class="wp-block-image aligncenter size-full is-resized has-custom-border" style="margin-bottom:var(--wp--preset--spacing--60)"><img decoding="async" width="801" height="479" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-8.png" alt="Automatic backup status with the 'Start' button highlighted." class="has-border-color wp-image-44323" style="border-color:#dfe6ee;border-width:2px;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px;width:800px" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-8.png 801w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-8-300x179.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-8-768x459.png 768w" sizes="(max-width: 801px) 100vw, 801px" /></figure>



<h3 id="h-restrict-control-panel-access" class="wp-block-heading"><strong>Restrict Control Panel Access</strong></h3>



<p class="wp-block-paragraph">To limit access to certain system settings, go to <strong>Security</strong> and <strong>Control panel access</strong> on the WinCC Unified Comfort Panel and click the checkbox to <strong>Enable password protection for control panel</strong>. This option requires a user with proper access to log in to use the WinCC Control panel, reducing the risk of accidental or unauthorized changes.</p>



<h3 id="h-automatic-runtime-start" class="wp-block-heading"><strong>Automatic Runtime Start</strong></h3>



<p class="wp-block-paragraph">To set a delay time before the automatic start of a project, click the icon with a wrench and a play button. This will open the Runtime Properties page. Locate the <strong>Automatic runtime start</strong> section and select a time from the &#8220;Waiting time(s)&#8221; dropdown menu. This is a very helpful setting to allow for some time before the automatic start to access the control panel.</p>



<h3 id="h-enable-smart-server-access" class="wp-block-heading">Enable Smart Server Access</h3>



<p class="wp-block-paragraph">Enabling <strong>Smart Server Access</strong> allows VNC access to the WinCC Unified Comfort Panel.</p>



<p class="wp-block-paragraph">To enable<strong> this setting</strong> in TIA Portal, go to <strong>Runtime settings</strong>, &gt; <strong>Remote Access</strong>, &gt; &nbsp;<strong>Smart Server</strong>. Click the <strong>Enable Smart Server</strong> checkbox. You must then configure unique passwords for each User1 and User2.</p>



<p class="wp-block-paragraph">If you wish to allow a user with that password to access the WinCC Unified Comfort Panel, click the <strong>Authorize User# for remote access to the panel</strong> checkbox. Upon your next download, the <strong>Smart Server</strong> will be enabled on the WinCC Unified Comfort Panel.</p>



<figure class="wp-block-image aligncenter size-full"><img decoding="async" width="1919" height="1045" src="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-9-1.png" alt="WinCC Unified Sm@rtServer configuration settings for a Siemens SIMATIC HMI Unified Comfort Panel with user password fields highlighted." class="wp-image-44370" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-9-1.png 1919w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-9-1-300x163.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-9-1-1024x558.png 1024w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-9-1-768x418.png 768w, https://static.dmcinfo.com/wp-content/uploads/2026/05/wincc-unified-comort-image-9-1-1536x836.png 1536w" sizes="(max-width: 1919px) 100vw, 1919px" /></figure>



<h3 id="h-firmware-updates" class="wp-block-heading"><strong>Firmware updates</strong></h3>



<p class="wp-block-paragraph">Depending on the panel and the version of TIA Portal you are using, you may need to update the device firmware prior to commissioning. If this is the case, follow these steps:</p>



<ol style="padding-top:0;padding-right:var(--wp--preset--spacing--60);padding-bottom:0;padding-left:var(--wp--preset--spacing--60)" class="wp-block-list">
<li style="padding-top:0;padding-bottom:var(--wp--preset--spacing--40)">It can be helpful to connect to the maintenance port on the HMI (PN-X2).</li>



<li style="padding-top:0;padding-bottom:var(--wp--preset--spacing--40)">Right-click the HMI in the Project Tree while the device is offline. Go to HMI device maintenance and select Update operating system.</li>



<li>TIA Portal will now prompt you to connect to the HMI via ethernet. Enter the IP address of the PN-X2 port. A pop-up with a progress bar should appear on the HMI, and a pop-up will appear on TIA Portal stating the firmware is being transferred.</li>
</ol>



<h3 id="h-date-and-time" class="wp-block-heading"><strong>Date and time</strong></h3>



<p class="wp-block-paragraph">Operators can also set a date and time on their panel by clicking the world icon in the sidebar menu. This will open the <strong>Language, Region and Formats/Date and time</strong> UI, allowing you to set your local date and time.</p>



<h2 id="h-synchronizing-time" class="wp-block-heading">Synchronizing Time</h2>



<p class="wp-block-paragraph">If the clocks between the HMI and PLC are not synchronized, HMI communication may be limited or blocked. If the HMI still cannot read tags from the PLC after following the steps above, first ensure the correct time zone is selected for the PLC. Then check the clock on the PLC through Online and Diagnostics. Under <strong>Functions &gt; Set Time</strong>, select <strong>Take from PG/PC Interface</strong> to synchronize the PLC with your PC.</p>



<h2 id="h-conclusion" class="wp-block-heading">Conclusion</h2>



<p class="wp-block-paragraph">Commissioning a WinCC Unified Comfort Panel is about more than getting screens to load. Proper network configuration, security settings, and runtime behavior all play a critical role in building a reliable, maintainable HMI system. By taking the time to configure encrypted transfers, user access, certificates, and startup behavior correctly, you set your system up for long-term success in the field.</p>



<p class="wp-block-paragraph" style="padding-bottom:var(--wp--preset--spacing--60)">Whether you are bringing a new HMI online, modernizing an existing system, or troubleshooting communication and security challenges, we can support you at any stage of the project. Partner with DMC to streamline your Siemens automation efforts and commission your systems with confidence.</p>



<div class="wp-block-group alignwide has-custom-light-blue-background-color has-background is-layout-flow wp-container-core-group-is-layout-dbd34961 wp-block-group-is-layout-flow" style="border-radius:20px;margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0">
<div class="wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-43efaee5 wp-block-columns-is-layout-flex" style="padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)">
<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:85%">
<h3 class="wp-block-heading has-text-align-left" id="h-have-an-upcoming-project-dmc-can-help-you-take-the-next-step">Need help with an upcoming project? DMC can help you take the next step.</h3>



<p class="has-text-align-left wp-block-paragraph" id="h-need-help-turning-ideas-into-outcomes-automation-project-to-the-next-level-contact-us-today-to-learn-more-about-our-solutions-and-how-we-can-help-you-achieve-your-goals">Move your next project forward with DMC&#8217;s <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/">Automation</a> experts to commission your next <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/hmi-and-scada-programming/siemens-simatic-wincc-programming/">HMI project</a> and design reliable systems that scale your operations.</p>
</div>



<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:15%">
<div class="wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2236275c wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-fill"><a class="wp-block-button__link has-base-contrast-color has-text-color has-link-color wp-element-button" href="https://static.dmcinfo.com/contact/">Contact Us</a></div>
</div>
</div>
</div>
</div>



<p class="wp-block-paragraph"></p>
<p>The post <a href="https://static.dmcinfo.com/blog/44303/wincc-unified-comfort-panel-commissioning-settings/">How to Commission a WinCC Unified Comfort Panel</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DMC St. Louis Goes Behind the Scenes at Anheuser-Busch </title>
		<link>https://static.dmcinfo.com/blog/38102/dmc-st-louis-goes-behind-the-scenes-at-anheuser-busch/</link>
		
		<dc:creator><![CDATA[Jackson Seida]]></dc:creator>
		<pubDate>Tue, 02 Sep 2025 13:00:00 +0000</pubDate>
				<category><![CDATA[Activities]]></category>
		<category><![CDATA[Culture]]></category>
		<category><![CDATA[St. Louis]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/?p=38102</guid>

					<description><![CDATA[<p>Every month, each DMC office has a budget from the Activity Fund to plan a social outing. The St. Louis team recently decided to put the Activity Fund to use by visiting a local icon together. We raised a glass on a behind-the-scenes tour of Anheuser-Busch Brewery.&#160; Anheuser-Busch offers several different tour experiences depending on [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/38102/dmc-st-louis-goes-behind-the-scenes-at-anheuser-busch/">DMC St. Louis Goes Behind the Scenes at Anheuser-Busch </a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Every month, each DMC office has a budget from the Activity Fund to plan a social outing. The St. Louis team recently decided to put the Activity Fund to use by visiting a local icon together. We raised a glass on a behind-the-scenes tour of Anheuser-Busch Brewery.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="900" height="600" src="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-1.jpg" alt="DMC STL colleagues under a Budweiser sign" class="wp-image-38107" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-1.jpg 900w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-1-300x200.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-1-768x512.jpg 768w" sizes="(max-width: 900px) 100vw, 900px" /></figure>



<p class="wp-block-paragraph">Anheuser-Busch offers several different <a href="https://www.budweisertours.com/stltours" target="_blank" rel="noreferrer noopener">tour experiences</a> depending on your interests and time available. We selected the Beermaster Tour which offers an exclusive behind-the-scenes look at how Budweiser is brewed.&nbsp;</p>



<p class="wp-block-paragraph">On the day of our tour, Dave Menne, Shannon Coupland, and I gathered at the famous brewery. We started our journey in the brewery’s visitor center excited to get access to exclusive locations on the campus. Then, we set off to learn about the King of Beers firsthand.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="900" height="600" src="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-2.jpg" alt="DMC STL colleagues in front of a mural" class="wp-image-38105" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-2.jpg 900w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-2-300x200.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-2-768x512.jpg 768w" sizes="(max-width: 900px) 100vw, 900px" /></figure>



<p class="wp-block-paragraph">We had a great time walking through the beer brewing process from start to finish. As engineers, we were fascinated by the bottling line. It was fun to see the high-speed automation and precision of the process in action. Tasting beer right from the chilled finishing tank was definitely a highlight. Although we’ve all tried Budweiser before, it tastes even better straight from the source.&nbsp;&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="900" height="600" src="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-4.jpg" alt="Three DMC colleagues at a brewery" class="wp-image-38104" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-4.jpg 900w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-4-300x200.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-4-768x512.jpg 768w" sizes="(max-width: 900px) 100vw, 900px" /></figure>



<p class="wp-block-paragraph">Another favorite moment of the tour was visiting the Budweiser Clydesdales. Not everyone can boast about a visit to the stables on their tour. The horses were just as majestic in person as they are on TV.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="900" height="600" src="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-3.jpg" alt="DMC STL colleagues in front of a Budweiser wagon" class="wp-image-38106" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-3.jpg 900w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-3-300x200.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/08/Anheuser-Busch-tour-3-768x512.jpg 768w" sizes="(max-width: 900px) 100vw, 900px" /></figure>



<p class="wp-block-paragraph">After the tour, we relaxed together with a meal at the brewery’s Biergarten restaurant. We laughed about our favorite parts of the tour and sampled a few more brews. It was a unique experience to see automation in action and get an all-access look at a local legend as a team.&nbsp;</p>



<div class="wp-block-group alignwide has-custom-light-blue-background-color has-background is-layout-flow wp-container-core-group-is-layout-dbd34961 wp-block-group-is-layout-flow" style="border-radius:20px;margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0">
<div class="wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-43efaee5 wp-block-columns-is-layout-flex" style="padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)">
<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:85%">
<h3 class="wp-block-heading has-text-align-left" id="h-have-an-upcoming-project-dmc-can-help-you-take-the-next-step">Come <em>brew</em> Something Great with Us. Join DMC.</h3>



<p class="has-text-align-left wp-block-paragraph" id="h-need-help-turning-ideas-into-outcomes-automation-project-to-the-next-level-contact-us-today-to-learn-more-about-our-solutions-and-how-we-can-help-you-achieve-your-goals">Interested in being part of a <a href="https://static.dmcinfo.com/careers/culture/" id="838">work environment</a> that values hard work and team-building? Learn what a <a href="https://static.dmcinfo.com/careers/" id="408">career</a> at DMC means and explore our <a href="https://static.dmcinfo.com/careers/open-positions/" id="835">open positions</a>.</p>
</div>



<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:15%">
<div class="wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2236275c wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-fill"><a class="wp-block-button__link has-base-contrast-color has-text-color has-link-color wp-element-button" href="https://static.dmcinfo.com/contact/">Contact Us</a></div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://static.dmcinfo.com/blog/38102/dmc-st-louis-goes-behind-the-scenes-at-anheuser-busch/">DMC St. Louis Goes Behind the Scenes at Anheuser-Busch </a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
