<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Rockwell Automation Archives | DMC, Inc.</title>
	<atom:link href="https://static.dmcinfo.com/blog/tag/rockwell-automation/feed/index.xml" rel="self" type="application/rss+xml" />
	<link></link>
	<description></description>
	<lastBuildDate>Fri, 04 Sep 2026 15:36:49 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://static.dmcinfo.com/wp-content/uploads/2025/04/site-icon-150x150.png</url>
	<title>Rockwell Automation Archives | DMC, Inc.</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How to Create a Configurable Routine Using Application Code Manager</title>
		<link>https://static.dmcinfo.com/blog/42127/how-to-create-a-configurable-routine-using-application-code-manager/</link>
		
		<dc:creator><![CDATA[Ray King]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 13:00:00 +0000</pubDate>
				<category><![CDATA[Allen Bradley PLC]]></category>
		<category><![CDATA[Manufacturing Automation & Intelligence]]></category>
		<category><![CDATA[Rockwell Automation]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/?p=42127</guid>

					<description><![CDATA[<p>This article will&#160;demonstrate how to&#160;build&#160;a library object for Application Code Manager&#160;(ACM).&#160;We will&#160;touch on&#160;instantiating&#160;AOIs&#160;using a library object&#160;in addition to&#160;adding&#160;optional&#160;logic to the code based on the&#160;object’s configuration.&#160;&#160; Utilizing ACM and configurable library objects&#160;allow you to&#160;streamline development&#160;by deterministically generating&#160;the code you need based on&#160;easy to&#160;modify&#160;configurations.&#160;This saves time, reduces mistakes, and&#160;enforces approved coding standards. While this blog illustrates&#160;the use [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/42127/how-to-create-a-configurable-routine-using-application-code-manager/">How to Create a Configurable Routine Using Application Code Manager</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This article will&nbsp;demonstrate how to&nbsp;build&nbsp;a library object for Application Code Manager&nbsp;(ACM).&nbsp;We will&nbsp;touch on&nbsp;instantiating&nbsp;AOIs&nbsp;using a library object&nbsp;in addition to&nbsp;adding&nbsp;optional&nbsp;logic to the code based on the&nbsp;object’s configuration.&nbsp;&nbsp;</p>



<p class="wp-block-paragraph">Utilizing ACM and configurable library objects&nbsp;allow you to&nbsp;streamline development&nbsp;by deterministically generating&nbsp;the code you need based on&nbsp;easy to&nbsp;modify&nbsp;configurations.&nbsp;This saves time, reduces mistakes, and&nbsp;enforces approved coding standards. While this blog illustrates&nbsp;the use of a few specific AOIs,&nbsp;the concept can be extended to any objects in your development library.&nbsp;</p>



<h2 id="h-planning-the-routines-nbsp-and-programs" class="wp-block-heading">Planning the Routines&nbsp;and Programs</h2>



<p class="wp-block-paragraph">The first step is to&nbsp;define the routines&nbsp;and programs&nbsp;within the library&nbsp;to&nbsp;organize the&nbsp;logic&nbsp;being generated.&nbsp;For this example, the alarm logic is organized&nbsp;in routines&nbsp;within the&nbsp;MainLogic&nbsp;program, which is dedicated to alarms and other control logic such as sequences.&nbsp;The&nbsp;MainProgram&nbsp;is used to organize&nbsp;and generate AOIs for&nbsp;devices, such as transmitters, into related routines.&nbsp;Both program names are intended to be placeholders and will be&nbsp;modified&nbsp;via parameter substitution in ACM.&nbsp;</p>



<p class="wp-block-paragraph">In this example, Analog Objects are configured with&nbsp;LoLo,&nbsp;Lo,&nbsp;Hi, and&nbsp;HiHi&nbsp;status thresholds. The&nbsp;Lo&nbsp;and&nbsp;Hi&nbsp;thresholds generate alarms, while&nbsp;LoLo&nbsp;and&nbsp;HiHi&nbsp;generate shutdown conditions. Alarm handling is contained within a dedicated&nbsp;Alarm&nbsp;routine, and shutdown handling is contained within a dedicated&nbsp;Shutdown&nbsp;routine, as illustrated in the figure below.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="276" height="128" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-1.png" alt="ACM display" class="wp-image-42149"/></figure>



<p class="wp-block-paragraph">Next,&nbsp;we’ll&nbsp;need to define the&nbsp;routine&nbsp;for&nbsp;our devices.&nbsp;For demonstration purposes, this routine will house the AOIs for&nbsp;processing and scaling the input data&nbsp;from either in-chassis IO or from a Turck IO block.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="244" height="72" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-2.png" alt="ACM display" class="wp-image-42150"/></figure>



<p class="wp-block-paragraph">For this example,&nbsp;we will use&nbsp;the name&nbsp;“myRoutine”&nbsp;so that we can&nbsp;later&nbsp;modify&nbsp;it&nbsp;via&nbsp;parameter substitution in ACM.&nbsp;&nbsp;</p>



<h2 id="h-programming-nbsp-the-routines" class="wp-block-heading">Programming&nbsp;the Routines</h2>



<p class="wp-block-paragraph">We will create an&nbsp;analog input routine&nbsp;consisting&nbsp;of two AOIs, AOI_TurckAnalogInputProcessing&nbsp;and&nbsp;AOI_AnalogInput.&nbsp;&nbsp;</p>



<h3 id="h-analog-input-routine" class="wp-block-heading">Analog Input Routine</h3>



<p class="wp-block-paragraph">The Analog Input routine will be structured&nbsp;to be fully configurable&nbsp;and&nbsp;allow the use with Turck I/O or without. This will be handled with configurable ACM parameters that will be explained later in the article. </p>



<p class="wp-block-paragraph">The Turck Analog Input Processing AOI is intended to be used with a BLCEN-8M12LT-4AI-VI-4A-VI. This AOI will combine the two Bytes which make up the analog input raw value, which will then be passed into&nbsp;<strong>iInRaw</strong>&nbsp;tag of the AOI&nbsp;AOI_AnalogInput&nbsp;via configurable ACM parameters. If Turck I/O was not being&nbsp;used&nbsp;ACM will not generate the Turck logic and will insert the user’s preferred I/O tag into&nbsp;<strong>iInRaw</strong>&nbsp;of the&nbsp;AOI_AnalogInput&nbsp;AOI.&nbsp;</p>



<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="624" height="272" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-3.png" alt="ACM display" class="wp-image-42151" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-3.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-3-300x131.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<h3 id="h-alarms-routine-nbsp" class="wp-block-heading">Alarms Routine&nbsp;</h3>



<p class="wp-block-paragraph">The Alarms routine will be used to configure&nbsp;alarm&nbsp;logic automatically if the&nbsp;AnalogInput&nbsp;is configured to have the corresponding Alarm(s). What does this mean?&nbsp;We will only generate&nbsp;Hi or Lo alarm logic if the input is configured to use them in ACM.&nbsp;In this example, we will&nbsp;use simple alarm bits with a global reset.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="158" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-4.png" alt="ACM display" class="wp-image-42152" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-4.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-4-300x76.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">Notice that the naming convention “C0000_myAnalog” matches the generic name of the&nbsp;AOI_AnalogInput&nbsp;that was&nbsp;added&nbsp;in&nbsp;the Analog Input Routine. This is done so we can use the&nbsp;parameter&nbsp;substitution feature&nbsp;in ACM&nbsp;to replace this text&nbsp;when generating code.&nbsp;</p>



<h3 id="h-shutdowns-routine-nbsp" class="wp-block-heading">Shutdowns Routine&nbsp;</h3>



<p class="wp-block-paragraph">Similar to&nbsp;the Alarms routine,&nbsp;HiHi&nbsp;and LoLo shutdowns will be added to the Shutdowns routine if&nbsp;the analog input is configured to use them.&nbsp;&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="224" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-5.png" alt="ACM display" class="wp-image-42154" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-5.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-5-300x108.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<h2 id="h-building-the-library-object-with-library-designer" class="wp-block-heading">Building the Library Object with Library Designer</h2>



<p class="wp-block-paragraph">From here,&nbsp;we’ll&nbsp;work within Rockwell’s Library&nbsp;Designer&nbsp;Plugin&nbsp;and configure the required&nbsp;text substitutions, parameters, and deterministic logic creation.&nbsp;</p>



<p class="wp-block-paragraph">Access the Library Designer plugin by right clicking the top of your controller organizer tree.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="468" height="174" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-6.png" alt="ACM display" class="wp-image-42155" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-6.png 468w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-6-300x112.png 300w" sizes="(max-width: 468px) 100vw, 468px" /></figure>



<p class="wp-block-paragraph">Once in Library Designer,&nbsp;navigate to “myRoutine” to get ready to apply conditional expressions that will handle logic creation.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="172" height="216" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-7.png" alt="ACM display" class="wp-image-42156"/></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="328" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-8.png" alt="ACM display" class="wp-image-42157" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-8.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-8-300x158.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">In Library&nbsp;Designer,&nbsp;you can&nbsp;set up&nbsp;instantiation rules per rung, per ladder branch,&nbsp;and&nbsp;even down to logic components like contacts and coiles. Here,&nbsp;we will be applying a rule for&nbsp;a&nbsp;rung&nbsp;containing&nbsp;the Turck AOI. Select the rung by&nbsp;clicking&nbsp;it. A green box will appear&nbsp;indicating&nbsp;that&nbsp;the&nbsp;rung has been selected.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="124" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-9.png" alt="ACM display" class="wp-image-42158" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-9.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-9-300x60.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">Update the condition to control the creation of the logic. By default,&nbsp;the library will have the field filled in with “Always.”</p>



<figure class="wp-block-image size-full"><img decoding="async" width="570" height="108" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-10.png" alt="ACM display" class="wp-image-42159" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-10.png 570w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-10-300x57.png 300w" sizes="(max-width: 570px) 100vw, 570px" /></figure>



<p class="wp-block-paragraph">This means that no matter what,&nbsp;this logic will always be created during the code generation process. For our&nbsp;example,&nbsp;we will&nbsp;only instantiate this logic&nbsp;if the configured IO&nbsp;is coming from a Turck IO device, which will be set using the parameter “<em>bTurckIO.</em>”&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="556" height="104" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-11.png" alt="ACM display" class="wp-image-42160" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-11.png 556w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-11-300x56.png 300w" sizes="(max-width: 556px) 100vw, 556px" /></figure>



<p class="wp-block-paragraph">This&nbsp;new&nbsp;parameter&nbsp;is&nbsp;added to the&nbsp;parameters section of our library object.&nbsp;&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="104" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-12.png" alt="ACM display" class="wp-image-42161" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-12.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-12-300x50.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">With&nbsp;that&nbsp;rule&nbsp;configured,&nbsp;the Turck AOI will only be included if the&nbsp;device is configured as a Turck IO point,&nbsp;while the Analog Input AOI will always be included when we instantiate one.&nbsp;We will leave the condition set to “Always” for the&nbsp;AOI_AnalogInput&nbsp;so that it will always be added for every input we configure.&nbsp;</p>



<p class="wp-block-paragraph">Next, we will&nbsp;use&nbsp;the same concept&nbsp;for&nbsp;the Alarms and Shutdowns routines. Just like the Turck object,&nbsp;we&nbsp;will&nbsp;create&nbsp;parameters&nbsp;to define if&nbsp;an alarm&nbsp;should exist.&nbsp;&nbsp;</p>



<p class="wp-block-paragraph">In the Alarms routine, we&nbsp;will apply&nbsp;a conditional&nbsp;parameter&nbsp;for both the Hi and Lo alarm rungs.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="64" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-13.png" alt="ACM display" class="wp-image-42163" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-13.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-13-300x31.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="566" height="98" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-14.png" alt="ACM display" class="wp-image-42165" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-14.png 566w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-14-300x52.png 300w" sizes="(max-width: 566px) 100vw, 566px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="56" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-15.png" alt="ACM display" class="wp-image-42166" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-15.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-15-300x27.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="560" height="94" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-16.png" alt="ACM display" class="wp-image-42167" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-16.png 560w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-16-300x50.png 300w" sizes="(max-width: 560px) 100vw, 560px" /></figure>



<p class="wp-block-paragraph">We&nbsp;will apply&nbsp;the same concept to the&nbsp;Shutdowns routine as well.&nbsp;These&nbsp;parameters are shown below.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="112" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-17.png" alt="ACM display" class="wp-image-42168" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-17.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-17-300x54.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">To&nbsp;demonstrate&nbsp;an&nbsp;additional&nbsp;option,&nbsp;we&nbsp;will add&nbsp;a conditional statement on the Alarms and Shutdown routines themselves. Just like choosing to instantiate rungs and small&nbsp;pieces&nbsp;of&nbsp;logic,&nbsp;you can choose to&nbsp;optionally&nbsp;create&nbsp;routines as well. Here,&nbsp;if no alarms&nbsp;or shutdowns&nbsp;are enabled,&nbsp;we will not create&nbsp;the respective routine.&nbsp;</p>



<p class="wp-block-paragraph">For Alarms we will require&nbsp;the&nbsp;following&nbsp;ACM parameters&nbsp;<strong>bAlarmLEnable&nbsp;</strong>(Low&nbsp;Alarm Enabled)&nbsp;or&nbsp;<strong>bAlarmHEnable&nbsp;</strong>(High Alarm Enabled) to be true.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="138" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-18.png" alt="ACM display" class="wp-image-42169" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-18.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-18-300x66.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">For Shutdowns&nbsp;we will require the following ACM parameters&nbsp;<strong>bAlarmHHEnable&nbsp;</strong>(High&nbsp;High&nbsp;Alarm Enabled),&nbsp;<strong>bAlarmLLEnable&nbsp;</strong>(Low&nbsp;Low&nbsp;Alarm Enabled), or&nbsp;<strong>bAlarmOREnable</strong>&nbsp;(Out of Range Alarm Enabled)&nbsp;to be true.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="76" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-19.png" alt="ACM display" class="wp-image-42170" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-19.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-19-300x37.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">From here, we can jump to the Application Code Manager and see how we can enter values into the parameters to affect what is created with the logic during code generation.&nbsp;</p>



<h2 id="h-application-code-manager-code-generation" class="wp-block-heading">Application Code Manager Code Generation</h2>



<p class="wp-block-paragraph">To&nbsp;continue with our demonstration, let’s&nbsp;add&nbsp;an Analog Input instance within ACM.&nbsp;For the first instance,&nbsp;we’ll&nbsp;configure it to&nbsp;require the Turck I/O without any alarms.&nbsp;To do&nbsp;so,&nbsp;we’ll&nbsp;need to concentrate on the following fields.&nbsp;</p>



<ul class="wp-block-list">
<li><strong>Name</strong>&nbsp;–&nbsp;This field specifies the device name and is used to generate the corresponding PLC tag name.&nbsp;</li>



<li><strong>sRoutineName</strong>&nbsp;– This field defines and creates the routine that&nbsp;the device will be instantiated in.&nbsp;</li>



<li><strong>b</strong><strong>TurkIO</strong>&nbsp;– This field is used to enable&nbsp;or disable&nbsp;the creation of Turck IO logic.&nbsp;&nbsp;</li>



<li><strong>AI_ADDRESS –&nbsp;</strong>This field is used&nbsp;to assign&nbsp;the I/O tag to the&nbsp;AnalogInput&nbsp;AOI. In this example we&nbsp;use “TIT_100.iInRaw” so that&nbsp;it&nbsp;can&nbsp;be referenced by the Turck AOI output.&nbsp;</li>
</ul>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="456" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-20.png" alt="ACM display" class="wp-image-42171" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-20.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-20-300x219.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">Next,&nbsp;we’ll&nbsp;create an&nbsp;Analog Input&nbsp;instance that does not use&nbsp;Turck IO but&nbsp;has&nbsp;all&nbsp;its&nbsp;alarms enabled.&nbsp;For now,&nbsp;I will put a placeholder into the&nbsp;AI_Address&nbsp;that can be configured later once I/O is&nbsp;configured in&nbsp;the project.&nbsp;&nbsp;Additional&nbsp;fields&nbsp;for alarm configuration&nbsp;will be used&nbsp;in this example.&nbsp;&nbsp;</p>



<ul class="wp-block-list">
<li><strong>bAlarmHHEnable</strong>&nbsp;–&nbsp;This field specifies&nbsp;if&nbsp;the High&nbsp;High&nbsp;alarm is enabled or disabled for the&nbsp;device.&nbsp;</li>



<li><strong>bAlarmH</strong><strong>Enable</strong>&nbsp;–&nbsp;This field specifies if the&nbsp;High&nbsp;alarm is enabled or disabled for the device.&nbsp;</li>



<li><strong>bAlarmLEnable</strong>&nbsp;–&nbsp;This field specifies if the&nbsp;Low&nbsp;alarm is enabled or disabled for the device.&nbsp;</li>



<li><strong>bAlarmLLEnable</strong>&nbsp;–&nbsp;This field specifies if the&nbsp;Low&nbsp;Low&nbsp;alarm is enabled or disabled for the device.&nbsp;</li>



<li><strong>bAlarmOREnable</strong>&nbsp;–&nbsp;This field specifies if the&nbsp;Out of Range&nbsp;alarm is enabled or disabled for the device.&nbsp;</li>
</ul>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="456" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-21.png" alt="ACM display" class="wp-image-42172" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-21.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-21-300x219.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">Now&nbsp;we’re&nbsp;ready to use ACM to&nbsp;generate our code.&nbsp;To do so,&nbsp;right click on the controller in ACM and click&nbsp;<strong>Generate Controller</strong>.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="610" height="780" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-22.png" alt="ACM display" class="wp-image-42173" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-22.png 610w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-22-235x300.png 235w" sizes="(max-width: 610px) 100vw, 610px" /></figure>



<p class="wp-block-paragraph">When the pop‑up dialog box appears, select&nbsp;<strong>Create ACD</strong>, enter the desired file name, select whether to overwrite the existing ACD file, and define the file path.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="780" height="240" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-23.png" alt="ACM display" class="wp-image-42174" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-23.png 780w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-23-300x92.png 300w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-23-768x236.png 768w" sizes="(max-width: 780px) 100vw, 780px" /></figure>



<p class="wp-block-paragraph">After you generate the .ACD file from&nbsp;ACM&nbsp;you will see that the following routines and programs have been created.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="320" height="128" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-24.png" alt="ACM display" class="wp-image-42175" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-24.png 320w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-24-300x120.png 300w" sizes="(max-width: 320px) 100vw, 320px" /></figure>



<p class="wp-block-paragraph">If we&nbsp;open&nbsp;the&nbsp;AnalogInputs&nbsp;routine, we will now see&nbsp;the two instances, TIT_100 and PIT_100 that were&nbsp;configured&nbsp;in ACM.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="324" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-25.png" alt="ACM display" class="wp-image-42176" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-25.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-25-300x156.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<p class="wp-block-paragraph">You’ll&nbsp;see that&nbsp;the Turck Interface created&nbsp;only for the TIT_100 object&nbsp;based on the parameters we set.&nbsp;Note that&nbsp;PIT_100&nbsp;was instantiated without the Turck AOI&nbsp;based on its parameterization.&nbsp;</p>



<p class="wp-block-paragraph">Now,&nbsp;let’s look at the newly generated&nbsp;Alarms and Shutdowns routines.&nbsp;In this example,&nbsp;alarms were&nbsp;only&nbsp;created for PIT_100&nbsp;as TIT_100 was not configured to use them.&nbsp;</p>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="164" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-26.png" alt="ACM display" class="wp-image-42177" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-26.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-26-300x79.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="624" height="244" src="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-27.png" alt="ACM display" class="wp-image-42178" srcset="https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-27.png 624w, https://static.dmcinfo.com/wp-content/uploads/2026/03/ACM-image-27-300x117.png 300w" sizes="(max-width: 624px) 100vw, 624px" /></figure>



<h2 id="h-conclusion" class="wp-block-heading">Conclusion</h2>



<p class="wp-block-paragraph">While this demonstration was simple in nature, it illustrates the benefits that can be derived by creating&nbsp;your own library objects and&nbsp;utilizing&nbsp;ACM to autogenerate&nbsp;a significant portion&nbsp;of your PLC logic.&nbsp;&nbsp;</p>



<p class="wp-block-paragraph">These concepts can be extended to create much more advanced programs and routines based on configurable parameters.&nbsp;For&nbsp;very large&nbsp;projects, or&nbsp;for OEMs with&nbsp;very similar&nbsp;systems, this can significantly streamline the development process.&nbsp;&nbsp;</p>



<p class="wp-block-paragraph">Here at DMC, we&nbsp;leverage&nbsp;ACM&nbsp;as a&nbsp;powerful&nbsp;tool&nbsp;to accelerate development timelines, improve code standardization, and&nbsp;quickly&nbsp;modify&nbsp;projects to account for changing requirements.&nbsp;&nbsp;</p>



<p class="wp-block-paragraph">For more information on&nbsp;Application Code Manager, read our&nbsp;other articles:&nbsp;&nbsp;</p>



<ul class="wp-block-list">
<li><a href="https://static.dmcinfo.com/blog/17355/streamline-rockwells-application-code-manager-with-excel/">Streamline Rockwell’s Application Code Manager with Excel</a>&nbsp;</li>



<li><a href="https://static.dmcinfo.com/blog/20684/importing-and-customizing-a-library-with-application-code-manager/">Importing and Customizing a Library with Application Code Manager</a></li>



<li><a href="https://static.dmcinfo.com/blog/17035/how-to-use-application-code-manager-acm-with-plantpax-distributed-control-system-dcs/">How to Use Application Code Manager (ACM) with PlantPAx Distributed Control System (DCS)</a></li>
</ul>



<div class="wp-block-group alignwide has-custom-light-blue-background-color has-background is-layout-flow wp-container-core-group-is-layout-dbd34961 wp-block-group-is-layout-flow" style="border-radius:20px;margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0">
<div class="wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-43efaee5 wp-block-columns-is-layout-flex" style="padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)">
<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:85%">
<h3 class="wp-block-heading has-text-align-left" id="h-have-an-upcoming-project-dmc-can-help-you-take-the-next-step"><strong>Accelerate your controls projects with scalable, reusable code solutions from DMC.</strong></h3>



<p class="has-text-align-left wp-block-paragraph" id="h-need-help-turning-ideas-into-outcomes-automation-project-to-the-next-level-contact-us-today-to-learn-more-about-our-solutions-and-how-we-can-help-you-achieve-your-goals">See how DMC uses ACM to streamline operations and standardize code for your <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/" id="420">Manufacturing Automation</a> project. Learn more about our <a href="https://static.dmcinfo.com/our-work/category/service/manufacturing-automation-and-intelligence/allen-bradley-plc/" data-type="work_category" data-id="689">Allen Bradley PLC</a> expertise.</p>
</div>



<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:15%">
<div class="wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2236275c wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-fill"><a class="wp-block-button__link has-base-contrast-color has-text-color has-link-color wp-element-button" href="https://static.dmcinfo.com/contact/">Contact Us</a></div>
</div>
</div>
</div>
</div>



<p class="wp-block-paragraph"></p>
<p>The post <a href="https://static.dmcinfo.com/blog/42127/how-to-create-a-configurable-routine-using-application-code-manager/">How to Create a Configurable Routine Using Application Code Manager</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Getting Started with FactoryTalk Logix Echo</title>
		<link>https://static.dmcinfo.com/blog/15859/getting-started-with-factorytalk-logix-echo/</link>
		
		<dc:creator><![CDATA[Aaron Shoemaker]]></dc:creator>
		<pubDate>Fri, 08 Nov 2024 15:05:12 +0000</pubDate>
				<category><![CDATA[PLC]]></category>
		<category><![CDATA[FactoryTalk Logix]]></category>
		<category><![CDATA[Rockwell Automation]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/blog/15859/getting-started-with-factorytalk-logix-echo/</guid>

					<description><![CDATA[<p>As system integrators, one of DMC’s primary goals is to be as efficient as possible when developing and deploying systems for our clients. The old-school method of sitting beside a machine to perform PLC testing is effective but inefficient. Studio 5000 Logix Emulate took the first steps towards moving us away from needing a fully [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/15859/getting-started-with-factorytalk-logix-echo/">Getting Started with FactoryTalk Logix Echo</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">As system integrators, one of DMC’s primary goals is to be as efficient as possible when developing and deploying systems for our clients. The old-school method of sitting beside a machine to perform PLC testing is effective but inefficient. <a href="https://static.dmcinfo.com/latest-thinking/blog/id/10141/emulate-a-studio-5000-controller-and-connect-to-a-factorytalk-view-me-project" target="_blank">Studio 5000 Logix Emulate</a> took the first steps towards moving us away from needing a fully built machine to test our code against, but it had limitations that often meant you still needed to test against real hardware.</p>



<p class="wp-block-paragraph">Enter FactoryTalk Logix Echo. Released by Rockwell Automation in 2021, Logix Echo is a <strong>full-fidelity PLC emulation tool</strong> that allows you to directly download and test any modern Rockwell PLC project – no controller or I/O changes required! This emulator behaves exactly as if it were a physical PLC sitting on your desk, which allows for significant testing of your PLC logic before you ever connect to the real machine. In cases where your project necessitates some form of digital twin – whether it be minimal I/O simulation or a full-fidelity machine model – tools like Emulate3D and Simulink can integrate with Logix Echo to provide full virtual commissioning functionality.</p>



<p class="wp-block-paragraph">At DMC, we make heavy use of FactoryTalk Logix Echo every day to allow Automation engineers in any of our offices to program and test PLC code before deployment for our customers. To do this, we set up a centralized Logix Echo server that many users can access at once. This blog will walk through the process of setting up a FactoryTalk Logix Echo server, creating an emulated PLC, downloading PLC programs, and connecting your simulated PLC to external Rockwell applications.</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/Logix-Echo-Server-Topology.png" alt="Using FactoryTalk Logix Echo on a server can support lots of developers at once."/></figure>



<p class="wp-block-paragraph"><p style="text-align: center;"><small><cite>Using FactoryTalk Logix Echo on a server can support lots of developers at once.</cite></small></p></p>



<h2 id="h-step-1-set-up-your-server" class="wp-block-heading">Step 1: Set Up Your Server</h2>



<h3 id="h-server-performance" class="wp-block-heading">Server Performance</h3>



<p class="wp-block-paragraph">Before you get started, make sure you have the right IT hardware for the job. From testing, we’ve found that each emulated PLC likes to take up <strong>one entire processor core and around 1GB of memory</strong> on the host computer. Excessive numbers of emulated PLCs on an undersized server can quickly lead to performance issues or cause some PLCs to lose their onboard programs. At DMC, we got around this problem by using a virtualized server with the following critical stats:</p>



<ul class="wp-block-list">
<li>Windows Server 2022</li>



<li>Intel Xeon processors @ 2.30 GHz</li>



<li>36 GB RAM</li>



<li>24 (virtual) processor cores</li>
</ul>



<p class="wp-block-paragraph">These stats work very well for us right now, but having a virtual server allows us to quickly add or remove processing resources as necessary to keep up with our customers’ project needs.</p>



<h3 id="h-network-provisioning" class="wp-block-heading">Network Provisioning</h3>



<p class="wp-block-paragraph">Since your Logix Echo server will be hosting many PLCs at once, it’s likely you’ll want to assign a unique IP address to each PLC. Fortunately, there’s a way to do this without running bundles and bundles of Ethernet cable to the same server! We’ve taken advantage of Windows’ ability to assign multiple IP addresses to the same physical Ethernet port on a PC.</p>



<p class="wp-block-paragraph">To do this, open the adapter properties for your (virtual) server’s network adapter, navigate to the IPv4 settings, and click the “Advanced” button on the bottom-right corner of the pop-up window. The “Advanced” pop-up window that opens allows you to add an arbitrary number of IP addresses. The server at DMC has over 10 IP addresses all running off the same physical Ethernet connection! This gives us a large pool of IP addresses to use when spinning up a brand-new Logix Echo PLC.</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/IP-Address-Setup.png" alt="Open the adapter properties for your virtual server’s network adapter"/></figure>



<p class="wp-block-paragraph">Once you have your server configured properly, install FactoryTalk Logix Echo using Rockwell’s install wizard.</p>



<h2 id="h-step-2-add-a-controller-to-your-server" class="wp-block-heading">Step 2: Add a Controller to Your Server</h2>



<p class="wp-block-paragraph">Now that we’ve got Logix Echo installed, it’s time to go ahead and set up our first emulated PLC! To do this, we’ll use the FactoryTalk Logix Echo Dashboard::</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/Launch-FTLE.png" alt="Use the FactoryTalk Logix Echo Dashboard to set up your first emulated PLC using the "/></figure>



<p class="wp-block-paragraph">The left-hand toolbar on the Logix Echo dashboard shows a list of all emulated PLCs that have been created on the server. Emulated ControlLogix controllers are hosted in a virtual chassis, just like a physical ControlLogix. Emulated CompactLogix controllers do not belong to a chassis.</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/FactoryTalk-Logix-Echo-Dashboard.png" alt="FactoryTalk Logix Echo Dashboard"/></figure>



<p class="wp-block-paragraph">To add a new controller (or chassis) to your Logix Echo server, right-click in any white space in the Devices toolbar or press the hamburger button on the top right-hand corner of the toolbar.</p>



<p class="wp-block-paragraph">Choosing “Add controller” will open a configuration pop-up window. Here, you will pick the controller type and firmware version, give your controller a name, and assign it to a chassis slot (if it’s a ControlLogix).</p>



<p class="wp-block-paragraph">Note that at the time this blog was published, only the following PLCs are available for emulation with Logix Echo:</p>



<ul class="wp-block-list">
<li>ControlLogix 5580 controllers
 
 
<ul class="wp-block-list">
<li>v33 through v36</li>
</ul>
</li>



<li>GuardLogix 5580 controllers
 
 
<ul class="wp-block-list">
<li>v35 and v36</li>
</ul>
</li>



<li>CompactLogix and Compact GuardLogix 5380 controllers
 
 
<ul class="wp-block-list">
<li>v36 only</li>
</ul>
</li>
</ul>



<p class="wp-block-paragraph">Before hitting “Add,” the last step is to assign an IP address to your controller. If you’ve assigned lots of IP addresses to your Echo server using the steps above, they will all appear in the drop-down menu here.</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/Set-Up-a-Logix-Echo-Controller.png" alt="ControlLogix 5580 Emulator"/></figure>



<p class="wp-block-paragraph">Once your controller has been added to the server, you can always go back and edit its properties by double-clicking on the device in the “Devices” toolbar on the left-hand side. This will open a status page on the main window of the dashboard where you can:</p>



<ul class="wp-block-list">
<li>Cycle controller “power”</li>



<li>Change the controller’s name and IP address</li>



<li>Change the assigned chassis or slot (for ControlLogix controllers only)</li>



<li>Attach or detach a simulated SD card to your controller
 
 
<ul class="wp-block-list">
<li><em>Yes, really! </em>Logix Echo creates a folder on your server that emulates file storage on an SD card connected to a physical controller – you use all the functions of a real SD card in your emulated PLC environment.</li>



<li>The server storage location for the emulated SD card is in<br>
  <code>C:\ProgramData\Rockwell Software\FactoryTalk Logix Echo\Controllers\&lt;your_controller&gt;\Root\sd</code></li>
</ul>
</li>
</ul>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/PLC-Status-Window.png" alt="FactoryTalk Logic Echo Dashboard"/></figure>



<h2 id="h-step-3-connect-to-your-echo-plc-and-get-programming" class="wp-block-heading">Step 3 – Connect to Your Echo PLC and Get Programming!</h2>



<p class="wp-block-paragraph">The next series of steps should be familiar to any Rockwell PLC programmer – since your emulated PLC is running and has an IP address, you should be able to browse it using FactoryTalk Linx. To make things easy for myself, I’ve created a whole Ethernet driver in FactoryTalk Linx specifically to browse for Logix Echo PLCs on DMC’s server. Keeping the Logix Echo PLCs segregated from physical ones in my Linx browser helps me remember what I’m connected to.</p>



<p class="wp-block-paragraph">Once your emulated PLC shows up in FactoryTalk Linx, you’ll notice that it will have a model number of <code>9310-WED300ENT</code>. Don’t panic! You can still download your ACD file without needing to change the controller type in your project – just make sure the firmware version of your project matches the firmware running on your Logix Echo PLC.</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/FactoryTalk-Linx-Setup.png" alt="FactoryTalk Linx Network Browser and Configuration Driver"/></figure>



<p class="wp-block-paragraph">Once you confirm you can successfully locate your PLC in FactoryTalk Linx, you should be able to perform the following Linx-based tasks:</p>



<ul class="wp-block-list">
<li>Connect and download an ACD file using FactoryTalk Logix Designer</li>



<li>Create a shortcut to the PLC inside a FactoryTalk View ME or SE application</li>



<li>Expose PLC tags to third-party software via OPC-UA using FactoryTalk Linx Gateway</li>



<li>Configure scheduled PLC program backups using FactoryTalk AssetCentre</li>
</ul>



<p class="wp-block-paragraph">We’ve used all these functions – plus plenty more advanced Logix Echo tricks – to continue to deliver quality solutions for customers.</p>



<div class="wp-block-group alignwide has-custom-light-blue-background-color has-background is-layout-flow wp-container-core-group-is-layout-dbd34961 wp-block-group-is-layout-flow" style="border-radius:20px;margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0">
<div class="wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-43efaee5 wp-block-columns-is-layout-flex" style="padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)">
<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:85%">
<h3 class="wp-block-heading has-text-align-left" id="h-have-an-upcoming-project-dmc-can-help-you-take-the-next-step"><strong>Test Rockwell PLC Code Before It Reaches the Machine</strong></h3>



<p class="has-text-align-left wp-block-paragraph" id="h-need-help-turning-ideas-into-outcomes-automation-project-to-the-next-level-contact-us-today-to-learn-more-about-our-solutions-and-how-we-can-help-you-achieve-your-goals">Explore our <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/" data-type="page" data-id="420">Automation</a> expertise in <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/hmi-and-scada-programming/rockwell-factorytalk-programming/factorytalk-optix-programming/" data-type="page" data-id="44850">FactoryTalk</a> Logix Echo for full-fidelity PLC emulation, digital twins, and virtual commissioning.</p>
</div>



<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:15%">
<div class="wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2236275c wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-fill"><a class="wp-block-button__link has-base-contrast-color has-text-color has-link-color wp-element-button" href="https://static.dmcinfo.com/contact/">Contact Us</a></div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://static.dmcinfo.com/blog/15859/getting-started-with-factorytalk-logix-echo/">Getting Started with FactoryTalk Logix Echo</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DMC Receives the 2024 Rockwell System Integrator Innovation Award</title>
		<link>https://static.dmcinfo.com/blog/16485/dmc-receives-the-2024-rockwell-system-integrator-innovation-award/</link>
		
		<dc:creator><![CDATA[DMC]]></dc:creator>
		<pubDate>Wed, 27 Mar 2024 14:54:43 +0000</pubDate>
				<category><![CDATA[Announcements]]></category>
		<category><![CDATA[Manufacturing Automation & Intelligence]]></category>
		<category><![CDATA[Rockwell Automation]]></category>
		<category><![CDATA[System Integrator]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/blog/16485/dmc-receives-the-2024-rockwell-system-integrator-innovation-award/</guid>

					<description><![CDATA[<p>DMC is proud to receive the 2024 Rockwell System Integrator Innovation Award at the 2024 PartnerNetwork Conference. “The Rockwell Network is huge, and there are a lot of great partners out there. We believe we are one of the best, but this is the first time we have attended PNC and been eligible to be [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/16485/dmc-receives-the-2024-rockwell-system-integrator-innovation-award/">DMC Receives the 2024 Rockwell System Integrator Innovation Award</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">DMC is proud to receive the 2024 Rockwell System Integrator Innovation Award at the <a href="https://www.rockwellautomation.com/en-us/company/news/press-releases/partnernetwork-conference-winners.html" target="_blank">2024 PartnerNetwork Conference</a>.</p>



<p class="wp-block-paragraph">“The Rockwell Network is huge, and there are a lot of great partners out there. We believe we are one of the best, but this is the first time we have attended PNC and been eligible to be recognized. Receiving this award is validation of what we can do as a company,” <a href="https://static.dmcinfo.com/about/employee-bios/jason-mayes">Jason Mayes</a>, Senior Director of DMC’s South Region, said. “Although we have not been a [Gold] member for long, we have been contributing to the industry for many years. We&#8217;ve been contributing to our customers for a long time, so receiving this award is not only recognition for a specific project or work we&#8217;ve done in a recent time frame, but is an indication of the quality of work we as an organization have been doing for many years.”</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/partner-network-awards-2024.jpg" alt="Partner Network Awards 2024"/></figure>



<p class="wp-block-paragraph">DMC proudly achieved Gold Partnership status in 2023: recognizing our demonstrated expertise in implementing Rockwell technologies and qualifying us to attend this annual four day exclusive, invitation-only event in Orlando, Florida. At the PartnerNetwork Conference, Rockwell Automation recognized and awarded those partners who have shown exemplary efforts in their Sustainability and Diversity, Equity, and Inclusion (DE&amp;I) programs and initiatives as well as their innovation to leverage Rockwell’s portfolio of products to help drive customer success.</p>



<p class="wp-block-paragraph">“The System Integrator Innovation Award recognizes DMC for demonstrating an innovation solution for their customer that helped solve and address business problems, drove transformation, and delivered meaningful and measurable business outcomes using best-in-breed technologies,” Amy L. Graff, North America Partner Marketing Manager at Rockwell Automation, said.</p>



<figure class="wp-block-image"><img decoding="async" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/system-integrator-innovation-award-banner-2024.png" alt="System Integrator Innovation Award Banner 2024"/></figure>



<p class="wp-block-paragraph">DMC is a long time Rockwell Automation partner and will continue to excel in implementing the best in breed technologies and solutions for our clients. We are honored to be recognized for our hard work, dedication, and our ability to design, develop, and deliver innovative solutions that allow our customers to reach new levels of success.</p>



<p class="wp-block-paragraph"><iframe loading="lazy" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen="" frameborder="0" height="290" referrerpolicy="strict-origin-when-cross-origin" scrolling="no" src="https://www.youtube.com/embed/eOajp8RwD3Y?si=RNI5SwDPraqta-Hy" width="560"><!--cke_bookmark_205S--><!--cke_bookmark_205E--></iframe></p>



<p class="wp-block-paragraph">&#8220;Receiving this award is a great honor and an incredible measure of validation. DMC’s motto is Smart People, Expert Solutions, and our goal was to deliver world class systems for every project,” <a href="https://static.dmcinfo.com/about/employee-bios/leon-grossman">Leon Grossman</a>, Senior Director of DMC&#8217;s Automation Service Area, said. “The Rockwell ecosystem [and] the Rockwell team have been huge bright spots for us as we’ve transitioned from a software only company to a company that delivers complete turnkey solutions. On behalf of everyone at DMC, we are honored to be awarded the Rockwell System Integrator Innovation Award at the 2024 PartnerNetwork Conference.”</p>



<div class="wp-block-group alignwide has-custom-light-blue-background-color has-background is-layout-flow wp-container-core-group-is-layout-dbd34961 wp-block-group-is-layout-flow" style="border-radius:20px;margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0">
<div class="wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-43efaee5 wp-block-columns-is-layout-flex" style="padding-right:var(--wp--preset--spacing--60);padding-left:var(--wp--preset--spacing--60)">
<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:85%">
<h3 class="wp-block-heading has-text-align-left" id="h-have-an-upcoming-project-dmc-can-help-you-take-the-next-step">Work with an Industry-Leading Integrator. Learn More About Working with DMC.</h3>



<p class="has-text-align-left wp-block-paragraph" id="h-need-help-turning-ideas-into-outcomes-automation-project-to-the-next-level-contact-us-today-to-learn-more-about-our-solutions-and-how-we-can-help-you-achieve-your-goals">Partner with DMC, a <a href="https://static.dmcinfo.com/about/partners/rockwell-automation-gold-system-integrator/" id="897">Rockwell Automation Gold System Integrator Partner</a>, and learn how our <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/" id="420">automation</a> experts can drive your next project to success.</p>
</div>



<div class="wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:15%">
<div class="wp-block-buttons is-horizontal is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2236275c wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-fill"><a class="wp-block-button__link has-base-contrast-color has-text-color has-link-color wp-element-button" href="https://static.dmcinfo.com/contact/">Contact Us</a></div>
</div>
</div>
</div>
</div>



<p class="wp-block-paragraph"></p>
<p>The post <a href="https://static.dmcinfo.com/blog/16485/dmc-receives-the-2024-rockwell-system-integrator-innovation-award/">DMC Receives the 2024 Rockwell System Integrator Innovation Award</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DMC Achieves Rockwell Automation Recognized System Integrator Certification</title>
		<link>https://static.dmcinfo.com/blog/19728/dmc-achieves-rockwell-automation-recognized-system-integrator-certification/</link>
		
		<dc:creator><![CDATA[Leon Grossman]]></dc:creator>
		<pubDate>Mon, 21 Sep 2020 12:24:26 +0000</pubDate>
				<category><![CDATA[Allen Bradley PLC]]></category>
		<category><![CDATA[Manufacturing Automation & Intelligence]]></category>
		<category><![CDATA[Rockwell Automation]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/blog/19728/dmc-achieves-rockwell-automation-recognized-system-integrator-certification/</guid>

					<description><![CDATA[<p>DMC has achieved the Rockwell Automation PartnerNetwork certification as a Recognized System Integrator. Rockwell Automation is a leader in automation. Their expertise is built off the understanding of the factory floor and business models that will make it the most productive. This partnership level recognizes and rewards DMC for the commitment we have made to [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/19728/dmc-achieves-rockwell-automation-recognized-system-integrator-certification/">DMC Achieves Rockwell Automation Recognized System Integrator Certification</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="wp-block-paragraph">DMC has achieved the Rockwell Automation PartnerNetwork certification as a Recognized System Integrator.</p>

<p class="wp-block-paragraph">Rockwell Automation is a leader in automation. Their expertise is built off the understanding of the factory floor and business models that will make it the most productive. This partnership level recognizes and rewards DMC for the commitment we have made to deliver expert solutions with a variety of different technologies and industries.&nbsp;</p>

<p class="wp-block-paragraph">They have created an unmatched partner network that stretches around the globe and expands daily. Customers value the&nbsp;PartnerNetwork as it provides exceptional support whenever and wherever. DMC is proud to recognize our expertise with Rockwell Automation technologies and platforms such as ControlLogix, CompactLogix, FactoryTalk View, Magnemotion, Kinetix Motion Controllers, PowerFlex VFD Drives, PanelView, and more.&nbsp;</p>

<p class="wp-block-paragraph">The PartnerNetwork will help DMC serve customers more effectively while working towards a thriving future for industrial automation. This certification identifies DMC as a company that offers knowledge and experience in design, implementation, project management, and maintenance of Rockwell Automation industrial control systems.</p>

<p class="wp-block-paragraph"><strong>Learn more about DMC&apos;s <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/plc-programming/allen-bradley-plc-programming">Rockwell Automation expertise</a>.&nbsp;</strong></p>
<p>The post <a href="https://static.dmcinfo.com/blog/19728/dmc-achieves-rockwell-automation-recognized-system-integrator-certification/">DMC Achieves Rockwell Automation Recognized System Integrator Certification</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>