<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Siemens Startdrive Archives | DMC, Inc.</title>
	<atom:link href="https://static.dmcinfo.com/blog/tag/siemens-startdrive/feed/index.xml" rel="self" type="application/rss+xml" />
	<link></link>
	<description></description>
	<lastBuildDate>Wed, 08 Jul 2026 22:08:03 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://static.dmcinfo.com/wp-content/uploads/2025/04/site-icon-150x150.png</url>
	<title>Siemens Startdrive Archives | DMC, Inc.</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Motion Control Solutions with Technology Objects in Siemens TIA Portal</title>
		<link>https://static.dmcinfo.com/blog/26884/motion-control-solutions-with-technology-objects-in-siemens-tia-portal/</link>
		
		<dc:creator><![CDATA[Otto Gottlieb]]></dc:creator>
		<pubDate>Fri, 13 Feb 2015 15:24:54 +0000</pubDate>
				<category><![CDATA[Manufacturing Automation & Intelligence]]></category>
		<category><![CDATA[Motion Control]]></category>
		<category><![CDATA[PLC]]></category>
		<category><![CDATA[Siemens PLC]]></category>
		<category><![CDATA[How To]]></category>
		<category><![CDATA[Siemens Startdrive]]></category>
		<category><![CDATA[Technology Objects]]></category>
		<category><![CDATA[TIA Portal]]></category>
		<guid isPermaLink="false">https://static.dmcinfo.com/blog/26884/motion-control-solutions-with-technology-objects-in-siemens-tia-portal-2/</guid>

					<description><![CDATA[<p>This article goes through setting up and using the Siemens S120 drive inside TIA Portal after configuration in STARTER. While several other Siemens drives can be started with Siemens Startdrive (G120, G120C, G120D, and G120P), performing a hardware configuration of an S120 drive is not yet integrated into TIA Portal. I have heard that the [&#8230;]</p>
<p>The post <a href="https://static.dmcinfo.com/blog/26884/motion-control-solutions-with-technology-objects-in-siemens-tia-portal/">Motion Control Solutions with Technology Objects in Siemens TIA Portal</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">This article goes through setting up and using the Siemens S120 drive inside TIA Portal after configuration in STARTER. While several other Siemens drives can be started with <a href="https://static.dmcinfo.com/latest-thinking/blog/id/8950/commissioning-siemens-g120-drives-with-startdrive-in-tia-portal">Siemens Startdrive</a> (G120, G120C, G120D, and G120P), performing a hardware configuration of an S120 drive is not yet integrated into TIA Portal. I have heard that the next big release will have this feature!</p>



<h2 class="wp-block-heading" id="h-tia-portal-setup">TIA Portal Setup</h2>



<p class="wp-block-paragraph">In this example project, I’m using an S7-1500 CPU and a CU320 control unit as seen in the below Network view.&nbsp;</p>



<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="800" height="214" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/1_s7-1500-CPU-and-CU320-control-unit-edited-1.jpg" alt="s7-1500-CPU-and-CU320-control-unit" class="wp-image-26867" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/1_s7-1500-CPU-and-CU320-control-unit-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/1_s7-1500-CPU-and-CU320-control-unit-edited-1-300x80.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/1_s7-1500-CPU-and-CU320-control-unit-edited-1-768x205.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph">In the Device View of the CU320, I select a DO SERVO Module and select its telegram from the Submodules. This telegram must match the telegram used when configuring the drive in STARTER.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="256" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/2_CU320-DO-Server-Module-1-edited-1.jpg" alt="CU320-DO-Server-Module" class="wp-image-26868" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/2_CU320-DO-Server-Module-1-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/2_CU320-DO-Server-Module-1-edited-1-300x96.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/2_CU320-DO-Server-Module-1-edited-1-768x246.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="243" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1.jpg" alt="CU320-DO-Server-Module" class="wp-image-26870" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1-300x91.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1-768x233.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="243" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1.jpg" alt="CU320-DO-Server-Module" class="wp-image-26870" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1-300x91.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/4_CU320-DO-Server-Module-3-edited-1-768x233.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph">Next, I add a Positioning Axis to the Technology objects.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="689" height="599" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/5_positioning-axis-technology-objects-1.png" alt="positioning-axis-technology-objects" class="wp-image-26871" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/5_positioning-axis-technology-objects-1.png 689w, https://static.dmcinfo.com/wp-content/uploads/2025/05/5_positioning-axis-technology-objects-1-300x261.png 300w" sizes="(max-width: 689px) 100vw, 689px" /></figure>



<p class="wp-block-paragraph"><span style="line-height: 20.7999992370605px;">And now I have a Positioning Axis in my project so that I can continue to do simple configuring.</span></p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="393" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/6-TIA-portal-simple-configuring-edited-1.jpg" alt="TIA-portal-simple-configuring" class="wp-image-26872" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/6-TIA-portal-simple-configuring-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/6-TIA-portal-simple-configuring-edited-1-300x147.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/6-TIA-portal-simple-configuring-edited-1-768x377.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph"><span style="line-height: 20.7999992370605px;">To compile successfully, the one action I must take is to assign the correct drive to this Technology Object.</span></p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="495" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/7_assign-drive-to-technology-object-edited-1.jpg" alt="assign-drive-to-technology-object" class="wp-image-26873" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/7_assign-drive-to-technology-object-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/7_assign-drive-to-technology-object-edited-1-300x186.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/7_assign-drive-to-technology-object-edited-1-768x475.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="315" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/8_assign-drive-to-technology-object-1.jpg" alt="assign-drive-to-technology-object" class="wp-image-26874" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/8_assign-drive-to-technology-object-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/8_assign-drive-to-technology-object-1-300x118.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/8_assign-drive-to-technology-object-1-768x302.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph"><span style="line-height: 20.7999992370605px;">TIA Portal’s Configuration tool has many items to customize for your application like Position Limits, Dynamic Limits, and Homing. It is worth exploring all available options to see if this configuration can make programming your application easier.</span></p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="583" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/9-TIA-portal-configuration-edited-1.jpg" alt="TIA-portal-configuration" class="wp-image-26875" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/9-TIA-portal-configuration-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/9-TIA-portal-configuration-edited-1-300x219.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/9-TIA-portal-configuration-edited-1-768x560.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<h2 class="wp-block-heading" id="h-tia-portal-commissioning">TIA Portal Commissioning</h2>



<p class="wp-block-paragraph">TIA Portal has several other useful tools to utilize once you download your project to the PLC:</p>



<ol class="wp-block-list">
<li>The Commissioning tool allows you to perform jogs, velocity moves, relative moves, absolute moves, and homing routines on your drive. I use this to determine the velocities, accelerations, decelerations, jerks, and homing routines I want to use in my application.</li>
</ol>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="340" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/10_tia-portal-comissioning-edited-1.jpg" alt="tia-portal-comissioning" class="wp-image-26876" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/10_tia-portal-comissioning-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/10_tia-portal-comissioning-edited-1-300x128.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/10_tia-portal-comissioning-edited-1-768x326.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph"><em>NOTE: If you have programmed the PLC to send commands to the drive. This tool does not let you activate the Axis until you disable those PLC commands. Remember to deactivate the Commissioning tool when finished (I have run into some problems when having an activated Axis when I disconnect from the PLC).</em></p>



<p class="wp-block-paragraph"><strong>WARNING: You need to be careful when using this so that you don’t harm anything or anybody.&nbsp;</strong></p>



<ol start="2" class="wp-block-list">
<li>The Diagnostics tool provides useful information about the servo when you are online with your controller. Use this information in the controller’s logic.</li>
</ol>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="361" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/11-tia-portal-diagnostics-tool-edited-1.jpg" alt="tia-portal-diagnostics-tool-" class="wp-image-26877" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/11-tia-portal-diagnostics-tool-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/11-tia-portal-diagnostics-tool-edited-1-300x135.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/11-tia-portal-diagnostics-tool-edited-1-768x347.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<h2 class="wp-block-heading" id="h-axis-programming">Axis Programming</h2>



<p class="wp-block-paragraph">Accessing the Diagnostics information inside my Ladder code is very helpful when programming axes, so I created a function block to do just that. As seen below, the Axis’s status word is sent into my function block, which is where I organized all its information into a data block that is more user-friendly.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="695" height="492" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/12_tia-portal-axis-programming-datablock-edited-1.png" alt="tia-portal-axis-programming-datablock" class="wp-image-26878" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/12_tia-portal-axis-programming-datablock-edited-1.png 695w, https://static.dmcinfo.com/wp-content/uploads/2025/05/12_tia-portal-axis-programming-datablock-edited-1-300x212.png 300w" sizes="(max-width: 695px) 100vw, 695px" /></figure>



<p class="wp-block-paragraph">The below screenshot shows the breakdown of the status word.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="565" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/13tia-portal-axis-commissioning-status-word-edited-1.jpg" alt="tia-portal-axis-commissioning-status-word" class="wp-image-26879" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/13tia-portal-axis-commissioning-status-word-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/13tia-portal-axis-commissioning-status-word-edited-1-300x212.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/13tia-portal-axis-commissioning-status-word-edited-1-768x542.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph">I assign each bit from the Positioning Axis’s status word into the function block’s corresponding Boolean.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="800" height="736" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/14_tia-portal-axis-function-block-edited-1.jpg" alt="tia-portal-axis-function-block" class="wp-image-26880" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/14_tia-portal-axis-function-block-edited-1.jpg 800w, https://static.dmcinfo.com/wp-content/uploads/2025/05/14_tia-portal-axis-function-block-edited-1-300x276.jpg 300w, https://static.dmcinfo.com/wp-content/uploads/2025/05/14_tia-portal-axis-function-block-edited-1-768x707.jpg 768w" sizes="(max-width: 800px) 100vw, 800px" /></figure>



<p class="wp-block-paragraph">To program the Axis’s movements, I placed all the built-in Siemens Technology Motion Control blocks into another function block as seen below.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="437" height="697" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/15_tia-portal-axis-movements-edited-1.png" alt="tia-portal-axis-movements" class="wp-image-26881" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/15_tia-portal-axis-movements-edited-1.png 437w, https://static.dmcinfo.com/wp-content/uploads/2025/05/15_tia-portal-axis-movements-edited-1-188x300.png 188w" sizes="(max-width: 437px) 100vw, 437px" /></figure>



<p class="wp-block-paragraph"><span style="line-height: 1.6;">Then I used some of the data from the Axis status word breakdown for the motion logic.</span></p>



<figure class="wp-block-image size-full"><img decoding="async" width="472" height="800" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/16_tia-portal-axis-motion-logic-edited-1.jpg" alt="tia-portal-axis-motion-logic" class="wp-image-26882" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/16_tia-portal-axis-motion-logic-edited-1.jpg 472w, https://static.dmcinfo.com/wp-content/uploads/2025/05/16_tia-portal-axis-motion-logic-edited-1-177x300.jpg 177w" sizes="(max-width: 472px) 100vw, 472px" /></figure>



<p class="wp-block-paragraph"><span style="line-height: 1.6;">I can also use data from the built-in Motion Control blocks for my logic. In this case, the MC_POWER block has a Status bit that is synonymous with the StatusWord.Enabled bit.</span></p>



<figure class="wp-block-image size-full"><img decoding="async" width="733" height="800" src="https://static.dmcinfo.com/wp-content/uploads/2025/05/17-tia-portal-motion-control-blocks-edited-1.jpg" alt="tia-portal-motion-control-blocks" class="wp-image-26883" srcset="https://static.dmcinfo.com/wp-content/uploads/2025/05/17-tia-portal-motion-control-blocks-edited-1.jpg 733w, https://static.dmcinfo.com/wp-content/uploads/2025/05/17-tia-portal-motion-control-blocks-edited-1-275x300.jpg 275w" sizes="(max-width: 733px) 100vw, 733px" /></figure>



<h2 class="wp-block-heading" id="h-summary">Summary</h2>



<p class="wp-block-paragraph">Siemens has made motion control applications simple and straightforward with TIA Portal.&nbsp;</p>



<ul class="wp-block-list">
<li>The Configuration and Commissioning tools create an easy commissioning process.</li>



<li>The Diagnostics tool helps online troubleshooting and programming.</li>



<li>The built-in Motion Control blocks are intuitive, and the Siemens help files provide additional information on how to utilize the Motion Control blocks effectively.</li>
</ul>



<p class="wp-block-paragraph">Learn more about <a href="https://static.dmcinfo.com/services/manufacturing-automation-and-intelligence/motion-control-engineering-and-servo-systems/">DMC&#8217;s motion control services</a> or <a href="https://static.dmcinfo.com/contact/">Contact Us</a> to get started on a project today.</p>
<p>The post <a href="https://static.dmcinfo.com/blog/26884/motion-control-solutions-with-technology-objects-in-siemens-tia-portal/">Motion Control Solutions with Technology Objects in Siemens TIA Portal</a> appeared first on <a href="https://static.dmcinfo.com/">DMC, Inc.</a>.</p>
]]></content:encoded>
					
		
		